Ball, gate, globe and check valves for LNG, LPG, ethylene and industrial gas service down to −196 °C — built to ISO 28921, BS 6364 and Shell MESC SPE 77/200, and tested in MT's own liquid-nitrogen test facility.
Applications listed in MT's cryogenic valve catalogue.
Sizes and classes as published in MT's cryogenic valve catalogue. Select a valve type for its full data.
| Valve type | Size & class |
|---|---|
| Floating ball valve | ½"–6" Class 150 / 300 · ½"–2" Class 600 · ½"–1½" Class 900 / 1500 |
| Trunnion mounted ball valve | 2"–24" Class 150 / 300 / 600 · 2"–12" Class 900 / 1500 |
| Gate valve | 2"–24" Class 150 / 300 / 600 / 900 / 1500 |
| Globe valve | 2"–12" Class 150 / 300 / 600 / 900 / 1500 |
| Check valve | 2"–24" Class 150 / 300 / 600 / 900 / 1500 |
| Dual plate check valve | Rated to −196 °C — see product page for the full range |
Common to MT cryogenic valves.
Extension length to Shell MESC SPE 77/200 gives enough vaporisation space to keep the stem packing warm enough to operate. The stem-to-bonnet gap is minimised to reduce cold loss.
Stops condensation on the bonnet dripping into the pipe insulation and freezing the line.
On valves with a body cavity — gate and ball valves — a relief hole faces upstream so trapped medium cannot over-pressurise the cavity.
A sleeve at the lower stem keeps alignment and sealing during operation, avoiding torque rise and stem scoring.
Gate, globe and check: CoCr-alloy hard-faced seats with seating width optimised for cryogenic service. Floating ball: spring-preloaded upstream seat. Trunnion ball: high-performance lip seals on seat, body and stem — single or double piston seat on request.
Low-emission gaskets and packing with controlled bolt torque. Designed and certified to the fugitive emission requirements of ISO 15848-1.
From MT's catalogue and company presentation.
Key components are placed in liquid nitrogen before final machining to improve the low-temperature stability of the austenitic stainless microstructure.
Controlled welding, cleaning and assembly in a clean assembly area, so dust particles cannot affect valve performance.
Full-size liquid-nitrogen pool, seat-leakage flowmeter, torque test machine and helium leak detector — tested to −196 °C with gas-detection alarm and oxygen monitoring.
Send your duty — medium, design temperature, size, class and standard — and our engineering team responds with drawings and lead time.